This
TFM type is a plain metallised film possessing high gloss.
The film has good adhesion to metal and coatings and exhibits
excellent barrier properties and processability. The film is suitable
for flexible packaging and lamination.
Corona
treated–metallised and chemical treated-metallised films with
metal side wound-in are also available for various packaging and
air-conditioning duct applications.
CIM
-- metal on corona and wound-in
COM -- metal on plain and corona wound-out
LIM
-- metal on chemical and wound-in
LOM -- metal on plain and chemical wound-out
|
TECHNICAL
DATA Type
– TFM (metal wound-in)
|
| PROPERTY |
TEST
METHOD |
UNIT |
NOMINAL
VALUE |
| PHYSICAL |
|
|
|
|
|
|
| Thickness |
Internal |
micron
|
10 |
11 |
12
|
23 |
| Yield |
Internal |
m2/kg |
71.4 |
64.9 |
59.5 |
31.0 |
| Tensile
Strength at Break MD |
ASTM-D-882 |
kg/cm2 |
2000 |
2000 |
2000 |
1850 |
|
TD |
|
|
2200 |
2200 |
2200
|
2200
|
| Elongation at
Break MD |
ASTM-D-882 |
% |
100 |
100 |
100 |
110 |
|
TD |
|
|
85 |
85 |
85 |
85 |
| Co-efficient of
Friction Static |
ASTM-D-1894 |
|
0.50 |
0.50 |
0.50 |
0.50 |
|
Kinetic |
|
|
0.45 |
0.45 |
0.45 |
0.45 |
| OPTICAL |
|
|
|
|
|
|
| Optical
Density |
|
|
2.0 |
2.0 |
2.0 |
2.0 |
| THERMAL |
|
|
|
|
|
|
| Shrinkage
at 150 o C/30’ MD |
ASTM-D-1204 |
% |
2.5 |
2.5 |
2.5 |
2.5 |
|
TD |
|
|
0.8 |
0.8 |
0.8 |
0.8 |
| BARRIER |
|
|
|
|
|
|
| MVTR
(380C/ 90% RH/ 24 hrs) |
ASTM-F-372 |
g/m2 |
|
|
0.8 |
0.7 |
| O2R
(250C/ 75% RH/ 24 hrs/ 1Atm.) |
ASTM-D-1434 |
cc/m2 |
|
|
1.25 |
1.15 |
MD--
Machine Direction ; TD–Transverse Direction
FDA
Status : This UmaPET polyester film complies with U.S. Food
and Drug Administration food additive regulation 21 CFR 177.1630,
sections (f) and (g).
UmaPETÒis
the registered trademark for Ester Industries’ bi-axially oriented
polyester films based on polyethylene terephthalate
The
information contained herein is to be used only as a guide for
using UmaPET film. The specifications and characteristics mentioned
are based on reliable test procedures. Users of this film should
make independent assessment of its suitability to their end use.
Ester Industries does not offer any guarantee on the results and
does not accept any liability arising out of the use of the information
contained herein.